| Snow loads | Snow loads of up to 1.35 kN/m² (higher snow loads in a special case on the North German Plain with individual proof) |
| Wind loads | High wind load requirements - In accordance with DIN 4112 (temporary buildings)
- And DIN 1055 (permanent use)
- Suitable for wind zone 3 (0.71 kN/m²)
|
| Effective height | - Full effective height up into the eave, without tension tie up into the ridge
- Heba-Fix® marquees don’t need any corner struts or junction plates
|
| Structures | - Particularly stable, low-wear and corrosion-free aluminium structures
- Can generally be erected with a forklift truck
|
| Roof | - White, translucent and stable industrial tarpaulin
- Easy inside tarpaulin as condensation protection
- Heba-Therm® tarpaulin for roof insulation
- Fixed roofs of trapezoidal sheet metal and insulated panels
|
| Side walls | Selection of- Tarpaulin (standard hire colour: similar to RAL 6026)
- Trapezoidal sheet metal (standard hire colour: RAL 9006)
- Insulated panels (standard hire colour: RAL 9006)
- On purchase: Colour can be selected from an extensive palette
|
| Tarpaulins | - Flame resistant in accordance with DIN 4102 B1
- Weight: 650 g/m²
- Load capacity of at least 250 kg per 5 cm tarpaulin
- Coating on both sides – on request, on the outside and the inside
- Available in various colours
- On purchase: Selection from an extensive colour palette (similar to RAL)
- Additional inside tarpaulin possible as condensation protection
|
| Tarpaulin gable | Multi-part tarpaulin gable- Increase windproofness
- Reduce wear and tear
|
| Heba-Therm® | Patent-protected Heba-Therm®- Insulated tarpaulin with heat transmission coefficients of min. 0.80 – max. 0.20 W/m² K
- Suitable for both tent roof and tent walls
- Flame resistant in accordance with DIN 4102 B1
|
| Gate integration | Easy and cheap installation of large gates in the side walls- Distance of 5 m between supports
(save costs for expensive steel lintel) - Thanks to fewer wind bracing fields, more gates can be integrated in the side walls
- Stable bolt lock for tarpaulin gates instead of simple straps
|
| Tubular steel in the tarpaulin pockets | Tubular steel in the tarpaulin pockets for even distribution of the bracing forces |
| Dywidag pressure bracing | Dywidag pressure bracing on the eave and floor of roof tarpaulins- Wear- and maintenance-free
- Protects against theft and vandalism
- Avoids water bulges
|
| Specially developed clamping profiles | Flexible clamping profiles for attaching fixed walls without rivets or screws
|